Product Details:
| Minimum Order Quantity | 1 Piece |
| Usage/Application | Industrial |
| Light Source | LED |
| Model Name/Number | ADP90 |
| Display | led |
| Weight | 42 kg |
| Brand | labman |
| Country of Origin | Made in India |
| Touch screen colour display | |
| Temperature display | |
| Faraday magneto-optical modulator | |
| Polarizer Polarizing film | |
| Digital Polarimeter based on Optical null principle | |
| No warm-up time is required when instrument is switched on | |
| Measuring multiple scales - specific rotation, optical rotation, sugar degree and concentration | |
| Automatic repetition-measurement for 6 times, and calculation of average value. | |
| Measurement of dark-coloured sample | |
| Response time 3°/sec. | |
| Insulated Sample chamber to keep sample temp. constant | |
| User can set retesting sample between 1 to 6 | |
| Photodiode Detector | |
| Data display - date, time, measuring mode, length of tube, temp. test time, measured value (1 - 6 values), average value, | |
| Purity method - saccharic concentration |
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Brand | Labtronics |
| Model Name/Number | LT-2400 |
| Country of Origin | Made in India |
| weight | 4.5 kg |
| Voltage | AC100~240V, 50/60Hz |
| Dimension (WxDxH) | 200x300x170 |
PCR Thermal Cycler (TOUCH SCREEN) Gradient Thermal Cycler (96x0.2ml) with adjustable pressure hot lid to
prevent volatilizing and dewing. Having long service life peltier. Ramping rate 5°C/s and cycle times
>1000,000.Android system, 5” large color touch screen, gradient function, wifi module builtin, big storage
capacity & support USB device, Time increment -1 secs to 600 secs, temperature increment 0.1 to 10.0°C. The
unique left-right design for amplification area and operating area.Temp. display accuracy ± 0.1°C, Gradient temp.
setting range 30-99 °C , Perform 20000 times non-breakdown operation. Block capacity 96 x 0.2 ml Temp range
4°C— 105°C, Max heating rate c 2.5°C/s. Max Cooling rate < 2.5°C/s. Temperature display accuracy 0.1°C, Max
Cycle Nos. 100. (HSN Code : 90273020)
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Wavelength Range | 190-1100 nm |
| Optical System | Single Beam |
| Spectral Bandwidth | 2 nm |
| Brand | Labtronics |
| Model No / Item Code | LT-291 |
| Wavelength Accuracy | +-0.2nm |
| Wavelength Repeatability | +-0.1nm |
| Photometric Accuracy | +-0.5%T or 0.003A@1A |
| Photometric Range | -0.3 to 3A, 0-200%T, 0-9999 conc. |
| Stability | +-0.002A/H@500nm |
| Detector | Silicon Photodiode |
| Display | 128x64 Dots large graphical LCD |
| Usage / Application | Laboratory |
| Dimensions | L700xB550xH340mm |
| Warranty | one year |
| Power | 230V+-10%AC, 50Hz |
| Voltage | 230V |
| Country of Origin | Made in India |
Single Beam Microprocessor UV-VIS Spectrophotometer (Advance Model) Range 190 to 1100 nm with facility
for automatic concentration, % Transmission, Absorbance & K Factor measurement. Automatic wavelength
calibration and selection. It has sample holder with 4 position selector control for 10 mm path length cuvettes.
Automatic wavelength calibration & wavelength scan. Automatic peak picking & spectrum display. Spectrum and
data can be printed out by printer and sent to computer via USB port. Set of 2 Quartz & 4 Glass. Highly stable and
accurate. SOFTWARE INCLUDED (HSN CODE : 90273020)
Additional Information:
Product Details:
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Spectral Bandwidth | 1 nm |
| Make | Accu-Msr |
| Model No- | AMUV1300 |
| Photometric Mode | T,A,C,E |
| Display | 7" TFT color screen |
| Light source | Deuterium & tungsten lamp |
| Detector | Silicon photodiode |
| power supply | AC220V / 501Hz |
| Gross weight | 30 kg |
Product Details:
| Minimum Order Quantity | 1 Piece |
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Spectral Bandwidth | 1 nm |
| Make | Accu-Msr |
| Model No | AMUV1500 |
| Scanning speed | Fast, Medium & Low |
| Display | LCD |
| Detector | Silicon photodiode |
| power supply | AC220 /50Hz |
| Gross weight | 30 kg |
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Spectral Bandwidth | 1/2/4/5 mm (variable) |
| Make | Accu-Msr |
| Model NO | AMUV1600 |
| Lamp | D2 lamp & tungsten halogen lamp (W lamp) |
| Scanning speed | Fast, Medium & Low |
| Data output port | USB Port |
| Display | LCD |
| Detector | silicon photodioded |
| power supply | AC 220V / 50Hz |
| Gross weight | 30 kg |
Additional Information:
Product Details:
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 1 nm |
| Brand | Labman |
| Model No / Item Code | LMSPUV1900 |
| Wavelength Accuracy | +- 0.5 nm |
| Wavelength Repeatability | +- 0.2 nm |
Digital Spectrophotometer:-
Standard Features:
The innovative optical layout and state of art mono- chromator with high grade blazed holographic grating ensure accuracy. Its integrated design assures long term stability and durability
The precisely aligned detector and quality deuterium and halogen lamps enhance the precision across the UV/vis spectrum starting from 190nm and into the near-infrared 1100nm
The two detectors are used to measure sample and reference respectively and simultaneously for optimizing measurement accuracy
Lamp Selection enables conserving the life of D2 & Tungsten lamp
Real-time clock for date and time stamping of results Large
Product Details:
| Minimum Order Quantity | 1 Piece |
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Spectral Bandwidth | 1 nm |
| Brand | Labtronics |
| Model No / Item Code | LT-1900 |
| Wavelength Accuracy | +-0.1nm |
| Wavelength Repeatability | +-0.1 nm |
| Photometric Accuracy | +-0.3%T or +-0.002A/h@1A |
| Stability | +-0.001A/h@500nm |
| Display | 10.1 inches colored touch screen |
| Usage / Application | Laboratory |
| Dimensions | 810x660x390mm |
| Warranty | one year |
| Power | 230V+-10%AC, 50Hz |
| Voltage | 230V |
| Weight | 27 kg |
| Country of Origin | Made in India |
Double Beam UV-VIS spectrophotometer (Touch Screen) Advance circuit measurement and control system make
the instrument of high reliability and low noise. Range 190-1100 nm, basic/ quantitative wavelength scan/DNA
Protein Test/Kinetic, automatic peak picking & spectrum display. Large Touch screen with colored display.
Spectrum and data can be printed out by printer and sent to computer via USB PORT. SOFTWARE INCLUDED (HSN
CODE : 90273020)
Additional Information:
Product Details:
| Wavelength Range | 200-1020nm |
| Optical System | Single Beam |
| Spectral Bandwidth | 2 nm |
| Brand | Labtronics |
| Model No / Item Code | LT-29 |
| Wavelength Accuracy | +-1nm |
| Wavelength Repeatability | 2.0nm |
| Photometric Accuracy | +-)0.5%T or 0.003A@1A |
| Photometric Range | -0.3 to 2A, 0-200%T, 0-9999 conc. |
| Detector | Silicon Photodiode |
| Display | LCD |
| Usage / Application | Laboratory |
| Warranty | one year |
| Power | 230V+-10%AC, 50Hz |
| Voltage | 230V |
| Country of Origin | Made in India |
Single Beam Microprocessor UV-VIS Spectrophotometer Range 195 to 1000 nm with facility for automatic
concentration, % Transmission, Absorbance & K Factor measurement. It has sample holder with 4 position selector
control for 10 mm path length cuvettes. Facility has been provided for interface with any printer (RS232). Set of 2
quartz and 4 glass cuvettes is provided. SOFTWARE INCLUDED (HSN CODE : 90273020)
Product Details:
| Minimum Order Quantity | 1 Piece |
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Spectral Bandwidth | 1 nm |
| Brand | Labtronics |
| Model No / Item Code | LT-2301 |
| Wavelength Accuracy | +-0.1nm |
| Wavelength Repeatability | +-0.1 nm |
| Photometric Accuracy | +-0.3%T or +-0.002A/h@1A |
| Stability | +-0.001 A/h@500nm |
| Display | 7 inches TFT colored Screen |
| Usage / Application | laboratory |
| Dimensions | 810x660x390mm |
| Warranty | one year |
| Power | 230V+-10%AC, 50Hz |
| Voltage | 230V |
| Weight | 27 kg |
| Country of Origin | Made in India |
Double Beam UV/VIS spectrophotometer (Xenon Lamp) Advance circuit measurement and control system make
the instrument of high reliability and low noise. Range 190-1100 nm, basic/ quantitative wavelength scan/DNA
Protein Test/Kinetic, automatic peak picking & spectrum display. Large colored screen with graphic display.
Spectrum and data can be printed out by printer and sent to computer via USB PORT. SOFTWARE INCLUDED (HSN
CODE : 90273020)
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Spectral Bandwidth | 1 nm |
| Brand | Labtronics |
| Model No / Item Code | LT-2205 |
| Wavelength Accuracy | +-0.1nm |
| Wavelength Repeatability | +-0.1 nm |
| Photometric Accuracy | +-0.3%T or +-0.002A/h@1A |
| Stability | +-0.001A/h@500nm |
| Display | 10.1 inches colored touch screen |
| Usage / Application | laboratory |
| Dimensions | 810x660x390mm |
| Warranty | one year |
| Power | 230V+-10%AC, 50Hz |
| Voltage | 230V |
| Weight | 27 kg |
| Country of Origin | Made in India |
Double Beam UV-VIS spectrophotometer (Touch Screen) Advance circuit measurement and control system make
the instrument of high reliability and low noise. Range 190-1100 nm, basic/ quantitative wavelength scan/DNA
Protein Test/Kinetic, automatic peak picking & spectrum display. Large Touch screen with colored display.
Spectrum and data can be printed out by printer and sent to computer via USB PORT. SOFTWARE INCLUDED (HSN
CODE : 90273020)
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Model No / Item Code | LT-790 |
| Resolution | 0.1 colour scale unit |
| Light Source | Incandescent lamp |
| Dimensions | 620x440x300 mm |
| Power | AC220V/50Hz & 50W |
| Voltage | 220V |
| Usage/ Application | Laboratory |
| Weight | 13 kg |
| Country of Origin | Made in India |
Visual Colorimeter is a kind of visual colour measuring instrument. It measures colour scale unit which is an
international acknowledged specific colour method. It has two modes transmittance & reflectance. Range 0.1-79.9
red, 0.1-79.9 yellow, 0.1-49.9 blue, 0.1-3.9 Neutral, resolution 0.1colour scale unit, viewing system- fully
adjustable.
Additional Information:
Product Details:
| Brand | LABMAN |
| Model Name/Number | ADP45 |
| Usage/Application | Laboratory |
| Size | STANDARD |
| Light Source | LED |
| Material | SS |
| Weight | 35kg |
| Digital Polarimeter |
Polarimeter instrument used to measure specific optical rotation of optically active substance |
| Built in auto controlling system with servomechanism | |
| Search Zero point automatically | |
| Auto judge substance form levorotatory or dextrorotatory | |
| Automatic measurement | |
| Storage of three times results | |
| Interface RS232 |
Product Details:
| Brand | LABMAN |
| Model Name/Number | ADP90 |
| Usage/Application | Laboratory |
| Size | STANDARD |
| Light Source | LED |
| Material | PLASTIC |
| Display | LED |
| Digital Polarimeter |
Polarimeter instrument used to measure specific optical rotation of optically active substance |
| Built in auto controlling system with servomechanism | |
| Search Zero point automatically | |
| Auto judge substance form levorotatory or dextrorotatory | |
| Automatic measurement | |
| Storage of three times results | |
| Interface RS232 |
Product Details:
| Minimum Order Quantity | 1 Piece |
| Wavelength Range | 320-1100nm |
| Optical System | Single Beam |
| Spectral Bandwidth | 2 nm |
| Brand | Labtronics |
| Model No / Item Code | LT-41 |
| Wavelength Accuracy | +- 0.5 nm |
| Wavelength Repeatability | +-0.3 nm |
| Photometric Accuracy | +-0.3%T or 0.003A@1A |
| Stability | +-0.002A/H@500nm |
| Display | 128x64 Dots Large Graphical LCD |
| Usage / Application | Laboratory |
| Warranty | one year |
| Country of Origin | Made in India |
Microprocessor Spectrophotometer (Scanning Based) Single Beam Range 320-1020 nm with facility for
automatic concentration, % Transmission and absorbance and K factor measurements. It has graphical LCD display
for data. Its sample holder accommodated glass cuvettes of 10 to 50 mm path length. Facility has been provided for
unlimited sample data storage and interface for any printer through USB. A set of 4 Glass cuvettes of 10 mm path
length is provided. INCLUDING SOFTWARE. (HSN CODE : 90273020)
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Wavelength Range | 190-1000 |
| Optical System | Single Beam |
| Mobility | Portable |
| Spectral Bandwidth | 2 nm |
| Brand | Labman |
| Model No / Item Code | LMSP-UV-1000 |
| Wavelength Accuracy | +-1.0 nm |
| Wavelength Repeatability | 0.5 |
| Photometric Accuracy | +-0.5% T |
| Photometric Range | -0.3-3A,0-200%T |
| Photometric Repeatability | +- 0.3% T |
| Stray Light | Less than equal to 0.3%T. |
| Stability | +- 0.002 A/h. |
| Lamp Type | Deuterium Lamp |
| Material | Plastic, steel |
| Display | Digital |
| Standard | ISO certified |
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Spectral Bandwidth | 5nm |
| Brand | Labtronics |
| Model No / Item Code | LT-31 |
| Wavelength Accuracy | +-2.5nm |
| Detector | Silicon Photodiode |
| Usage / Application | Laboratory |
| Dimensions | L475xB285xH130mm |
| Warranty | one year |
| Power | 230V+-10%AC, 50Hz |
| Voltage | 230V |
| Weight | 8.5 kg |
| Country of Origin | Made in India |
Digital Spectrophotometer (Double Display) Range 340-960 nm with facility for automatic concentration,
% Transmission and absorbance measurements. 3½ digit data display, separate 3 digit LED display for wavelength
in nm with 1nm wavelength resolution. (HSN CODE : 90273020)
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Spectral Bandwidth | 5nm |
| Brand | Labtronics |
| Model No / Item Code | LT-38 |
| Wavelength Accuracy | +-2.5nm |
| Detector | Silicon Photodiode |
| Usage / Application | Laboratory |
| Dimensions | L475xB285xH130mm |
| Warranty | one year |
| Power | 230V+-10%AC, 50Hz |
| Voltage | 230V |
| Weight | 8.5 kg |
| Country of Origin | Made in India |
Digital Spectrophotometer (Double Display) Range 340-960 nm with facility for automatic concentration, 6%
Transmission and absorbance measurements. 3½ digit data display, separate 3 digit LED display-For wavelength in
nm with 1 nm wavelength resolution. Provision for 10 mm & 50 mm path length cuvettes is provided equipped with
set of 10 mm & 50 mm path length cuvettes. (HSN CODE : 90273020)
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Brand | Labtronics |
| Model Name/Number | LT-241 |
| Country of Origin | Made in India |
| Temp.range | 4-99.9 DegreeC |
| Sample capacity | 32x0.2ml |
| LCD | 5 inch, 800x480 pixel |
| Input power | 24V, 8A |
| Dimensions | W.200xD.230xH.85mm |
| Net weight | 3.2 kgs |
PCR Thermal Cycler (TOUCH SCREEN) Gradient Thermal Cycler (32x0.2ml) with adjustable pressure hot lid to
prevent volatilizing and dewing. Having long service life peltier. Ramping rate 5°C/s and cycle times
>1000,000.Android system, 5” color touch screen, gradient function, wifi module builtin, big storage capacity &
support USB device, Time increment -1 secs to 600 secs, temperature increment 0.1 to 10.0°C. The unique leftright
design for amplification area and operating area. Perform 20000 times non-breakdown operation. Block
capacity 32 x 0.2 ml Temp range 4°C— 100°C, Max heating rate c 2.5°C/s. Max Cooling rate < 2.5°C/s.
Temperature display accuracy 0.1°C, Max Cycle Nos. 100. (HSN Code : 90273020)
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Brand | labman |
| Model Name/Number | pcr9602g |
| Country of Origin | Made in India |
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Burner | titanium burners for C2 H2 -N20 & C2H2-AIR |
| Brand | Labtronics |
| Nebulizer | fully inert nebulizer |
| Model No / Item Code | LT-2102 |
| Usage / Application | Laboratory |
| Dimensions | L100xH55xW58 cm |
| Warranty | one year |
| Power | 220/240 VAC, 50/60 Hz, 800VA |
| Weight | 65 kg |
| Country of Origin | Made in India |
Atomic Absorption Spectrophotometer (Double Beam) Atomic Absorption Spectrophotometer Ebert type
monochromator with 1200 lines/ mm halographic grating, 0 to2nm SBW, 190-900nm Wavelength range. 8 hollow
cathode Lamp turret assembly with modulated eight independent power supplies. Built in background corrector in
the system using high intensity and high speed Deuterium lamp. Automatic calibration using up to maximum 10
standards and recalibration with a single standard. Direct concentration readout using different modes (K- Factor
Linear regression and Quadratic regression). Display of the signal energy in the form of BAR signal and numeric
form. ABS. % TRANS and CONC display facility. Absorbance range from 0 to 3.0 ABS. Titanium Burner of 100 mm
Air-acetylene and 50 mm N 20 - Acetylene Flames. Corrosion resistant nebulizer with Platinum - Iridium capillary,
Impact bead. Supplied with computer interface software, cylinder, regulator, 3 standard lamps & compressor.
(HSN CODE : 90273020)
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Brand | Labtronics |
| Nebulizer | Fully inert nebulizer |
| Model No / Item Code | LT-2100 |
| Usage / Application | Laboratory |
| Dimensions | L100xH55xW58cm |
| Warranty | one year |
| Power | 220/240VAC, 50/60Hz, 800VA |
| Weight | 65 kg |
| Country of Origin | Made in India |
Atomic Absorption Spectrophotometer (Single Beam) Atomic Absorption Spectrophotometer Ebert type
monochromator with 1200 lines/ mm halographic grating, 0 to2nm SBW, 190-900nm Wavelength range. 8 hollow
cathode Lamp turret assembly with modulated four independent power supplies. Built in background corrector in
the system using high intensity and high speed Deuterium lamp. Automatic calibration using up to maximum 10
standards and recalibration with a single standard. Direct concentration readout using different modes (K- Factor
Linear regression and Quadratic regression). Display of the signal energy in the form of BAR signal and numeric
form. ABS. % TRANS and CONC display facility. Absorbance range from 0 to 3.0 ABS. Titanium Burner of 100 mm
Air-acetylene and 50 mm N 20 - Acetylene Flames. Corrosion resistant nebulizer with Platinum - iridium capillary,
Impact bead. Supplied with computer interface software, cylinder, regulator, 3 standard lamps & compressor.
(HSN CODE : 90273020)
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Spectral Bandwidth | 1/2/4/5 (variable) |
| Make | Accu-Msr |
| Model No | AMUV1400 |
| Photometric Mode | T,A,C,E |
| Display | 7" TFT color screen |
| Light source | Deuterium &tungsten lamp |
| Detector | silicon photodiode |
| power supply | AC 220V /50Hz |
| Gross weight | 30 kg |
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Model Name/Number | LT-4100 |
| Detector | DTGS |
| Weight | 24 kg |
| Voltage | 230V |
| Usage/ Application | Laboratory |
| Make | Labtronics |
| Dimension | 540x520x260 mm |
| power supply | 230V+-10%, 50Hz |
Spectrometer Spectral Range : 7800 to 350cm Resolution: Better than 0.85 cm Wave number Precision :
± 0.01cm¯?1; Scanning Speed: 5 steps adjustable for different Applications, signal to noise ratio: better than
15,000:1 (RMS value, at 2100 cm¯?1; ion Resolution: 4 cm-1 Detector: DTGS, 1 minute data collection Beam Splitter.
Ge coated Kbr, Infrared Source: Air-cooled. high efficiency Reflex sphere module. Detector: DTGS, Data System:
Computer Compatible Software: FTIR Software contains all routines library needed for basic spectrometer
operations. Including library search, quantitation and spectrum. (HSN CODE : 90189099)Accessories on Demand
(HSN CODE : 90189099)Attenuated Total Reflection (ATR) Hydraulic press for FT-IR (15 Tons)KBr die set for pallet
making – 7mm Pallet holder KBr powder 100gm Agate mortar pestle 2” size Universal liquid cell holder
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Wavelength Range | 320-1020nm |
| Spectral Bandwidth | 4 nm |
| Brand | Labtronics |
| Model No / Item Code | LT-39 |
| Wavelength Accuracy | 2nm |
| Photometric Accuracy | +- 0.1% T |
| Photometric Repeatability | 0.5%T |
| Stability | +-0.004A/H (500nm pregeat 1 hour) |
| Display | 4 modes LCD |
| Usage / Application | Laboratory |
| Warranty | one year |
| Power | 220V/110VAC, 50Hz |
| Voltage | 220V |
| Country of Origin | Made in India |
Microprocessor Spectrophotometer(VIS) Range 320-1020 nm with facility for automatic concentration,
% Transmission and absorbance and K factor measurements. It has 3½ Bright LCD display for data. Its sample
holder accommodated glass cuvettes of 10 to 50 mm path length. Facility has been provided for unlimited sample
data storage and interface for any printer through RS 232 C.A set of 4 Glass cuvettes of 10 mm path length is
provided. INCLUDING SOFTWARE. (HSN CODE : 90273020)
Additional Information: